Product Details
- Parameters Measured:Ls/ Lp/ Cs/ Cp/ Rs/ R p/ D/ Q/ Θ/ ESR / L C R auto selection
- LCD Display:Dual 19999/ 1999 display & bar graph 51 segment
- Measuring rate:Approx. 2 times per second
- Range:Automatic
- Overload:”OL” Display On LCD
-
Low Battery:
Display On LCD - Auto Power Off:In 5 Minutes Approx.
- Battery:9V x1
- Safety standard:IEC 61326-1 & IEC 61326-2-2
Features:
- Auto L/C/R check
- 100 / 120 / 1K / 10K / 100K Hz test frequency
- 20,000 / 2,000 counts display
- Backlight
- Ls/ Lp/ Cs/ Cp/ Rs/ Rp/ DCR with D/Q/θ/ESR measurement
- Relative mode
- Series / Parallel modes
- Components sorting function
*Selectable tolerance ±0.25%、±0.5%、± 1%、±2%、±5%、±10%、±20%、-20%+80% - Low battery indication
- 4-wire Kelvin measurement
Measurement Ranges:
Accuracy: ±(% of reading + number of least significant digits) at 23°C ± 5°C, <75% R.H.
1. Specifications are based on measurement performed at input sockets or terminals with Alligator Test Lead Case (TL-21) after short & open calibration.
2. DUT ( device under test ) & Test leads should be properly shielded to GUARD if necessary.
3. To make better precision measurements on extremely high or low impedance ranges of L,C,R, it is highly recommended that do OPEN/SHORT calibration before measuring for following ranges marked with *
Resistance(Parallel / Series mode):
|
Range |
Resolution |
100/120Hz |
1kHz |
10kHz |
100kHz |
|
20.000Ω |
0.001Ω |
─ |
1.0%+3* |
1.0%+3* |
2.0%+3* |
|
200.00Ω |
0.01Ω |
1.0%+3 |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
2.0000kΩ |
0.0001kΩ |
0.3%+2 |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
20.000kΩ |
0.001kΩ |
0.3%+2 |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
200.00kΩ |
0.01kΩ |
0.5%+2 |
0.5%+2 |
0.5%+2 |
1.0%+3 |
|
2.0000MΩ (2.000MΩ) |
0.0001MΩ |
1.0%+3 |
1.0%+3 |
1.0%+3 |
─ |
|
0.001MΩ |
─ |
─ |
─ |
2.0%+3* |
|
|
20.000MΩ (20.00MΩ) |
0.001MΩ |
2.0%+3* |
2.0%+3* |
─ |
─ |
|
0.01MΩ |
─ |
─ |
2.0%+3* |
─ |
|
|
200.0MΩ |
0.1MΩ |
2.0%+3* |
2.0%+3* |
─ |
─ |
* Do open/short calibration before measuring for above ranges with * to have better precision measurements.
DCR
|
Range |
Resolution |
Accuracy |
|
200.00Ω |
0.01Ω |
1.0%+3* |
|
2.0000kΩ |
0.0001kΩ |
0.2%+2 |
|
20.000kΩ |
0.001kΩ |
0.2%+2 |
|
200.00kΩ |
0.01kΩ |
0.5%+2 |
|
2.0000MΩ |
0.0001MΩ |
1.0%+3 |
|
20.000MΩ |
0.001MΩ |
2.0%+3* |
|
200.0MΩ |
0.1MΩ |
2.0%+3* |
** Do open/short calibration before measuring for above ranges with * to have better precision measurements.
Capacitance (Parallel / Series mode):
|
Range |
Resolution |
100/120Hz |
1kHz |
10kHz |
100kHz |
|
200.00pF |
0.01pF |
─ |
─ |
1.2%+5* |
2.0%+5* |
|
2000.0pF |
0.1pF |
─ |
2.0%+3* |
0.3%+2 |
0.6%+3 |
|
20.000nF |
0.001nF |
2.0%+3* |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
200.00nF |
0.01nF |
0.3%+2 |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
2000.0nF |
0.1nF |
0.3%+2 |
0.3%+2 |
0.6%+2 |
2.0%+5* |
|
20.000μF (20.00μF) |
0.001μF |
0.3%+2 |
0.6%+2 |
1.2%+5* |
─ |
|
0.01μF |
─ |
─ |
─ |
3.0%+5 (10μF max.)* |
|
|
200.00μF (200.0μF) |
0.01μF |
0.6%+2 |
1.0%+3* |
─ |
─ |
|
0.1μF |
─ |
─ |
3.0%+5 (100μF max.)* |
─ |
|
|
2000.0μF (2000μF) |
0.1μF |
1.0%+3* |
─ |
─ |
─ |
|
1μF |
─ |
1.2%+3* |
─ |
─ |
|
|
20.00mF |
0.01mF |
1.2%+3* |
─ |
─ |
─ |
*If reading <2000, unit on display is pF
* Do open/short calibration before measuring for above ranges with * to have better precision measurements.
Inductance (Parallel / Series mode).
|
Range |
Resolution |
100/120Hz |
1kHz |
10kHz |
100kHz |
|
20.000μH |
0.001μH |
─ |
─ |
─ |
2.5%+5* |
|
200.00μH |
0.01μH |
─ |
─ |
1.2%+5* |
0.6%+3 |
|
2000.0μH |
0.1μH |
─ |
2.0%+5* |
0.6%+3 |
0.6%+3 |
|
20.000mH |
0.001mH |
1.2%+5* |
1.0%+5 |
0.3%+2 |
0.6%+3 |
|
200.00mH |
0.01mH |
0.3%+2 |
0.6%+3 |
0.3%+2 |
1.2%+5* |
|
2000.0mH |
0.1mH |
0.3%+2 |
0.3%+2 |
0.6%+3 |
─ |
|
20.000H |
0.001H |
0.3%+2 |
0.6%+3 |
1.2%+5* |
─ |
|
200.0H |
0.1H |
0.6%+3 |
1.2%+5* |
─ |
─ |
|
2.000KH |
0.001KH |
1.2%+5* |
─ |
─ |
─ |
*If reading <2000, unit on display is μH
* Do open/short calibration before measuring for above ranges with * to have better precision measurements.
Accuracy v.s. Resistance (ZDUT)
|
|
DCR |
100/120Hz |
1kHz |
10kHz |
100kHz |
|
0.1~1Ω |
1.2%+5* |
1.2%+5* |
1.2%+5* |
1.2%+5* |
2.5%+5* |
|
1~10Ω |
0.6%+3* |
0.6%+3* |
0.6%+3* |
0.6%+3* |
1.2%+5* |
|
10~100kΩ |
0.3%+2 |
0.3%+2 |
0.3%+2 |
0.3%+2 |
0.6%+3 |
|
100k~1MΩ |
0.6%+3 |
0.6%+3 |
0.6%+3 |
0.6%+3 |
2.5%+5* 100k~2MΩ |
|
1M~20MΩ |
1.2%+5* |
1.2%+5* |
1.2%+5* |
2.5%+5* |
|
|
>20MΩ |
2.5%+5* |
2.5%+5* |
2.5%+5* |
─ |
─ |
* Do open/short calibration before measuring for above ranges with * to have better precision measurements.
TEMP./Humidity:
- Operation:0°C~ 50°C(32℉~122℉)/<70% R.H.(no condensation)
- Storage:-20°C~ 60°C(-4℉~140℉)/<80%R.H.(no condensation)
Dimension & Weight:
- 188(L)x95(W)x52(H)mm
- Approx.350g (excluding battery)
Accessories:
- Alligator test lead case (TL-21) x 1
- AC/DC Adaptor x 1
- Guard Line (TL-23) x 1
- TL-22 SMD Tweezers x 1
- DC 9V Battery x1
- Instruction Manual x1
- Carry case x 1



Additional Accessories for with USB Function:
- Optical IR to USB PC link x 1
- CD Rom (software) x
Reviews
Shipping & Returns
Returns Policy
In the event that you are not 100% satisfied with any product you purchase, you may return it to us within 30 days of order receipt and exchange it, receive a credit on your account or a refund on your credit card. The product to be returned must be unused and in saleable condition (i.e., in original, unmarked, undamaged packaging). A minimum restocking fee of 25% will be applied to all returns.
You will not receive a credit for the returned product until the merchandise is received at our facility in Los Angeles, California.
When returning a merchandise which was initially offered free shipping, the amount to be refunded will be the price of the returned merchandise less the initial shipping charge.
After 30 days from the date of the purchase, no return will be accepted.
Shipping
We make every effort to ship purchases within 24 hours of receiving your order. Orders submitted after 1pm PST will be processed on the next business day. Weekend delivery service is NOT available.
Please use street addresses where possible; PO Boxes will be shipped with USPS only; UPS and Fedex does not ship to PO Boxes.
If an item(s) on your order is out of stock, you can request a backorder and will be shipped and charged to you as soon as the item becomes available.
In the event that the shipped out package is returned to us due to the fact that no receiver was available at the requested delivery destination, the purchaser is responsible for both the outgoing and returning shipping charges. If the package is returned, a refund will be issued LESS the original outbound shipping cost and return shipping cost.
Transit times are only estimates and not guaranteed especially during the holiday season and for orders that offered free shipping.